  伪故障一:医用感应自动门无论人们是否经过,它都不停开启或关闭。
  Pseudo fault 1: no matter whether people pass by or not, the medical induction automatic door keeps opening or closing.
  1.可能探测器的感应范围有其它活动物体进入,检查医用感应自动门周围移除其它或动物体;
  1. It is possible that there are other moving objects in the sensing range of the detector. Check that other or animal bodies are removed around the automatic medical sensing door;
  2.可能传感器的检测范围调的太低,当门将关闭时,探头和传感器感应到门感应到活动,误认为是移动的物体通过,将门再次打开;
  2. The detection range of the sensor may be adjusted too low. When the door is going to be closed, the probe and the sensor sense that the door senses activity, mistakenly believing that the moving object passes through, and the door is opened again;
              济南玻璃隔断
  3.可能是由于固定感应探头的上梁板有松动现象,造成探头抖动,以致门扇不停开关。
  3. It may be that the upper beam plate of the fixed induction probe is loose, which causes the probe to vibrate, so that the door leaf does not stop switching.
  伪故障二:医用感应自动门在运行时声音大时,这样的故障大多由于自动门已使用了较长时间。
  Pseudo fault 2: when the medical induction automatic door is loud in operation, most of such faults are due to the automatic door has been used for a long time.
  1.门扇吊具的走轮经过很长一段时间的磨损(零部件失效的一种基本类型),如只有轻微的磨损(零部件失效的一种基本类型),可以清洗轨道和走轮,也可以加一点润滑油在走轮轴承上,但是不能给轨道和塑性走轮上注油,因为注油后易吸灰尘,使走轮损坏更快,如配件损坏严重应及时更换维修;
  1. After a long period of wear (a basic type of parts failure), the walking wheel of the door leaf spreader can be cleaned or a little lubricating oil can be added to the bearing of the walking wheel. However, it is not allowed to inject oil into the track and plastic walking wheel, because it is easy to absorb dust after oil injection, which makes the walking wheel damaged faster, such as equipped with The damaged parts shall be replaced and repaired in time;
  2.部分金属连接件有松动现象,只需再加固即可;
  2. Some metal connectors are loose, only need to be reinforced;
  3.活动门扇与固定门扇有摩擦现象而出现噪音(分贝(dB));
  3. There is friction between movable door leaf and fixed door leaf, resulting in noise (DB);
  4.下部导向系统的损坏,也会造成声音大的现象;
  4. The damage of the lower guide system will also cause loud sound;
  5.上梁在更初施工时做得不好,或与天花板吊顶产生了共振现象。
  5. The upper beam is not well done in the initial construction or has resonance with the ceiling.
  伪故障三:医用感应自动门的门扇反应迟缓
  False fault three: slow response of medical automatic induction door
  1.感应探头的探测范围太小,对感应范围进行调整即可;
  1. The detection range of the induction probe is too small, so adjust the sensing range;
  2.感应探头内部有积尘现象,清理灰尘;
  2. There is dust accumulation in the inner part of the induction probe, clean the dust;
  3.门体太重,超出了主机的马达牵引力。
  3. The door body is too heavy, which exceeds the motor traction of the main engine.
  伪故障四:医用感应自动门的门扇不动,那么你应该看看是否要充电了。
  Pseudo fault 4: the door leaf of the medical induction automatic door does not move, so you should see if you want to charge it.
  1.看门扇是否有拖地开的现象,如果出现这种现象,门启动时会很吃力,主控制器会认为有障碍而进行自锁保护,使门停止运行;
  1. Check whether the door leaves are pulled open. If this happens, the door will be very hard to start. The main controller will think there is an obstacle and carry out self-locking protection to stop the operation of the door;
  2.看门扇的吊轮是不是从轨道中脱落下来,如果出现这种现象,门扇也会停止不走。
  2. Check whether the hoisting wheel of the door leaf falls off from the track. If this happens, the door leaf will also stop.
  注意:只有做好维护保养工作才能减少伪故障发生率,提高医用感应自动门使用寿命。
  Note: only doing well in maintenance can reduce the incidence of false fault and improve the service life of medical induction automatic door.
  以上是对感应自动门故障的分析,想要了解更多内容欢迎点击济南感应自动门官方网站。